Voltage Class
|
115V Class
|
230V Class
|
460V Class
|
|
Model Number VFD-XXXS
|
002
|
004
|
007
|
002
|
004
|
007
|
015
|
022
|
004
|
007
|
015
|
022
|
|
Max. Applicable Motor Output (kW)
|
0.2
|
0.4
|
0.75
|
0.2
|
0.4
|
0.75
|
1.5
|
2.2
|
0.4
|
0.75
|
1.5
|
2.2
|
|
Max. Applicable Motor Output (HP)
|
0.25
|
0.5
|
1.0
|
0.25
|
0.5
|
1.0
|
2.0
|
3.0
|
0.5
|
1.0
|
2.0
|
3.0
|
|
Output Rating
|
Rated Output Capacity (KVA)
|
0.6
|
1.0
|
1.6
|
0.6
|
1.0
|
1.6
|
2.9
|
4.2
|
1.2
|
2.0
|
3.3
|
4.4
|
|
Rated Output Current (A)
|
1.6
|
2.5
|
4.2
|
1.6
|
2.5
|
4.2
|
7.5
|
11.0
|
1.5
|
2.5
|
4.2
|
5.5
|
|
Maximum Output Voltage (V)
|
3-phase Proportional to Twice the Input Voltage
|
3-phase Proportional to Input Voltage
|
|
Rated Frequency (Hz)
|
1.0 to 400 Hz
|
|
Input Rating
|
Rated Input Current (A)
|
Single phase
|
Single/3-phase model drive
|
3-phase
|
|
6
|
9
|
18
|
4.9/
1.9
|
6.5/
2.7
|
9.7/
5.1
|
15.7/9.0
|
24/
15
|
1.7
|
2.9
|
5.1
|
6.9
|
|
Input Current for 1-phase model drive to be used as 3-phase model drive
|
-- --
|
1.6
|
3.0
|
5.1
|
8.4
|
--
|
-- --
|
|
Rated Voltage/Frequency
|
100/110/120 VAC 50/60 Hz
|
200/208/220/240 VAC
50/60Hz
|
380/400/415/480 VAC 50/60Hz
|
|
Voltage/Freq. Tolerance
|
Voltage: ±10%, Frequency: ±5%
|
|
Control
Characteristics
|
Control System
|
SPWM (Sinusoidal Pulse Width Modulation, carrier frequency 3k-10kHz)
|
|
Output Frequency Resolution
|
0.1Hz
|
|
Torque Characteristics
|
Including the auto-torque, auto-slip compensation; starting torque can be 150% at 5Hz
|
|
Overload Endurance
|
150% of rated current for 1 minute
|
|
Accel/Decel Time
|
0.1to 600 second (2 Independent settings for Accel/Decel Time)
|
|
V/F Pattern
|
V/F pattern adjustable
|
|
Stall Prevention Level
|
20 to 250%, Setting of Rated Current
|
|
Operating Characteristics
|
Frequency Setting
|
Keypad
|
Setting by or Potentiometer
|
|
External Signal
|
Potentiometer-5KW/0.5W, DC 0 to +10V or 0 to +5V (Input impedance 47KW), RS-485 interface, 4 to 20mA (Input impedance 250W); Multi-Function Inputs 1 to 5 (7 steps, Jog, up/down)
|
|
Operation Setting Signal
|
Keypad
|
Setting by RUN, STOP
|
|
External Signal
|
M0 to M5 can be combined to offer various modes of operation, RS-485 serial interface (MODBUS).
|
|
Multi-Function Input Signal
|
Multi-step selection 0 to7, Jog, accel/decel inhibit, first/second accel/decel switch, counter, 8-step PLC operation, external Base Block (NC, NO), increase/decrease Master Frequency
|
|
Multi-Function Output Indication
|
AC Drive Operating, Frequency Attained, Non-zero, Base Block, Fault Indication, Local/Remote indication, PLC Operation indication.
|
|
Analog Output Signal
|
Analog frequency/current signal output.
|
|
Other Function
|
AVR, S-Curve, Over-Voltage/Over-Current Stall Prevention, Fault Records, Adjustable Carrier Frequency, DC Braking, Start Frequency for DC Braking, Momentary Power Loss restart, Frequency Limits, Parameter Lock/Reset, PID Feedback Control, Reverse Inhibition, etc.
|
|
Built-in EMI Filter
|
VFD002S21E, VFD004S21E, VFD004S43E, VFD007S21E, VFD007S43E, VFD015S21E, VFD015S43E, VFD022S21E, VFD022S43E
|
|
Protection
|
Self-testing, Over Voltage, Over Current, Under Voltage, Overload, Overheating, External Fault, Electronic thermal, Ground Fault.
|
|
Cooling
|
Forced air-cooling (ONLY FOR 022S2XA/B; XXXS43A/B/E 1HP~3HP; XXXSXXD; XXXS21E 400W~3HP). Others are Natural air-cooling.
|
|
Environment
|
Installation Location
|
Altitude 1,000 m or below, keep from corrosive gasses, liquid and dust
|
|
Pollution Degree
|
2
|
|
Ambient Temperature
|
-10°C to 40°C (Non-Condensing and not frozen)
|
|
Storage Temperature
|
-20°C to 60°C
|
|
Ambient Humidity
|
Below 90% RH (non-condensing)
|
|
Vibration
|
9.80665m/s2 (1G) less than 20Hz, 5.88m/s2 (0.6G) at 20 to 50Hz
|