VFD-B
The VFD-B series is a general purpose NEMA 1 drive and offers V/F, Sensorless Vector and Closed Loop Vector control. With its Constant Torque rating and 0-2000Hz output, the VFD-B is designed to handle most conventional drive applications found in the industrial manufacturing industry. The VFD-B series drives are used in many applications including: HVAC, Compressor, Crane Gantry, Elevator, Escalator, Material Handling, Water/Wastewater, and Woodworking to name a few.
|
|
|
|
VFD-B Specifications
|
Voltage Class
|
230V Class
|
|
Model Number VFD-XXXB
|
007
|
015
|
022
|
037
|
055
|
075
|
110
|
150
|
185
|
220
|
300
|
370
|
|
Max. Applicable Motor
Output (kW)
|
0.75
|
1.5
|
2.2
|
3.7
|
5.5
|
7.5
|
11
|
15
|
18.5
|
22
|
30
|
37
|
|
Max. Applicable Motor
Output (hp)
|
1.0
|
2.0
|
3.0
|
5.0
|
7.5
|
10
|
15
|
20
|
25
|
30
|
40
|
50
|
|
Output Rating
|
Rated Output Capacity kVA)
|
1.9
|
2.5
|
4.2
|
6.5
|
9.5
|
12.5
|
18.3
|
24.7
|
28.6
|
34.3
|
45.7
|
55.0
|
|
Rated Output Current (A)
|
5.0
|
7.0
|
11
|
17
|
25
|
33
|
49
|
65
|
75
|
90
|
120
|
145
|
|
Maximum Output Voltage (V)
|
3-Phase Proportional to Input Voltage
|
|
Output Frequency (Hz)
|
0.1~400 Hz
|
|
Carrier Frequency (kHz)
|
1-15
|
1-9
|
|
Input Rating
|
Rated Input Current (A)
|
Single/3-phase
|
3-phase
|
|
11.9/
5.7
|
15.3/
7.6
|
22/
15.5
|
20.6
|
26
|
34
|
50
|
60
|
75
|
90
|
110
|
142
|
|
Input Current for 1-phase models when using 3-phase power
|
7.0
|
9.4
|
14.0
|
--
|
|
Rated Voltage/Frequency
|
Single/3-phase
200-240 V, 50/60Hz
|
3-phase
200-240V, 50/60Hz
|
|
Voltage Tolerance
|
10%(180~264 V)
|
|
Frequency Tolerance
|
5%(47~63 Hz)
|
|
Cooling Method
|
Natural
|
Fan Cooled
|
|
Weight (kg)
|
2.7
|
3.2
|
4.5
|
6.8
|
8
|
10
|
13
|
13
|
13
|
13
|
36
|
36
|
|
Voltage Class
|
460V Class
|
|
Model Number VFD-XXXB
|
007
|
015
|
022
|
037
|
055
|
075
|
110
|
150
|
185
|
220
|
300
|
370
|
450
|
550
|
750
|
|
Max. Applicable Motor Output (kW)
|
0.75
|
1.5
|
2.2
|
3.7
|
5.5
|
7.5
|
11
|
15
|
18.5
|
22
|
30
|
37
|
45
|
55
|
75
|
|
Max. Applicable Motor Output (hp)
|
1.0
|
2.0
|
3.0
|
5.0
|
7.5
|
10
|
15
|
20
|
25
|
30
|
40
|
50
|
60
|
75
|
100
|
|
Output Rating
|
Rated Output Capacity (kVA)
|
2.3
|
3.2
|
4.2
|
6.5
|
9.9
|
13.7
|
18.3
|
24.4
|
28.9
|
34.3
|
45.7
|
55.6
|
69.3
|
84
|
114
|
|
Rated Output Current (A)
|
2.7
|
4.2
|
5.5
|
8.5
|
13
|
18
|
24
|
32
|
38
|
45
|
60
|
73
|
91
|
110
|
150
|
|
Maximum Output Voltage (V)
|
3-phase Proportional to Input Voltage
|
|
Output Frequency (Hz)
|
0.1~400 Hz
|
|
Carrier Frequency (kHz)
|
1-15
|
1-9
|
1-6
|
|
Input Rating
|
Rated Input Current (A)
|
3-phase
|
|
|
4.3
|
|
11.2
|
|
|
|
|
|
|
|
|
|
130
|
160
|
|
Rated Voltage
|
3-phase 380 to 480 V
|
|
Voltage Tolerance
|
10%(342~528 V)
|
|
Frequency Tolerance
|
5%(47~63 Hz)
|
|
Cooling Method
|
Natural
|
Fan Cooled
|
|
Weight (kg)
|
2.7
|
3.2
|
4.5
|
6.8
|
8
|
10
|
13
|
13
|
13
|
13
|
36
|
36
|
36
|
50
|
50
|
|
Voltage Class
|
575V Class
|
|
Model Number VFD-XXXB
|
007
|
015
|
022
|
037
|
055
|
075
|
110
|
150
|
185
|
220
|
300
|
370
|
450
|
550
|
750
|
|
Max. Applicable Motor Output (kW)
|
0.75
|
1.5
|
2.2
|
3.7
|
5.5
|
7.5
|
11
|
15
|
18.5
|
22
|
30
|
37
|
45
|
55
|
75
|
|
Max. Applicable Motor Output (hp)
|
1.0
|
2.0
|
3.0
|
5.0
|
7.5
|
10
|
15
|
20
|
25
|
30
|
40
|
50
|
60
|
75
|
100
|
|
Output Rating
|
Rated Output Capacity (kVA)
|
1.7
|
3.5
|
4.5
|
7.5
|
10
|
13.4
|
18.9
|
21.9
|
26.9
|
33.9
|
40.8
|
51.8
|
61.7
|
79.7
|
99.6
|
|
Rated Output Current (A)
|
1.7
|
3.5
|
4.5
|
7.5
|
10
|
13.5
|
19
|
22
|
27
|
34
|
41
|
52
|
62
|
80
|
100
|
|
Maximum Output Voltage (V)
|
3-phase Proportional to Input Voltage
|
|
Output Frequency (Hz)
|
0.1~400 Hz
|
|
Carrier Frequency (kHz)
|
1-10
|
1-8
|
1-6
|
|
Input Rating
|
Rated Input Current (A)
|
3-phase
|
|
1.2
|
3.1
|
4.0
|
8.3
|
10.3
|
13.8
|
18.2
|
22
|
27.7
|
32
|
41
|
52
|
62
|
74
|
91
|
|
Rated Voltage
|
3-phase 500 to 600 V
|
|
Voltage Tolerance
|
-15% ~ +10% (425~660V)
|
|
Frequency Tolerance
|
5% (47~63Hz)
|
|
Cooling Method
|
Natural
|
Fan Cooled
|
|
Weight (kg)
|
2.7
|
3.2
|
4.5
|
6.8
|
8
|
10
|
13
|
13
|
13
|
13
|
36
|
36
|
36
|
50
|
50
|
|
General Specifications
|
|
Control Characteristics
|
Control System
|
SPWM(Sinusoidal Pulse Width Modulation) control (V/f or sensorless vector control)
|
|
Frequency Setting Resolution
|
0.01Hz
|
|
Output Frequency Resolution
|
0.01Hz
|
|
Torque Characteristics
|
Including the auto-torque, auto-slip compensation; starting torque can be 150% at 1.0Hz
|
|
Overload Endurance
|
150% of rated current for 1 minute
|
|
Skip Frequency
|
Three zones, settings range 0.1-400Hz
|
|
Accel/Decel Time
|
0.1 to 3600 seconds (4 Independent settings for Accel/Decel time)
|
|
Stall Prevention Level
|
20 to 250%, setting of rated current
|
|
DC Brake
|
Operation frequency 0.1-400.0Hz, output 0-100% rated current
Start time 0-60 seconds, stop time 0-60 seconds
|
|
Regenerated Brake Torque
|
Approx. 20%(up to 125% possible with option brake resistor or brake unit externally mounted, 1-15HP brake chopper built-in)
|
|
V/f Pattern
|
Adjustable V/f pattern, 1.5 power curve, 1.7 power curve, square and cube curve
|
|
Operating Characteristics
|
Frequency Setting
|
Keypad
|
Setting by 
|
|
External Signal
|
Potentiometer-5kW/0.5W, 0 to +10VDC; -10 to +10VDC, 4 to 20mA RS-485 interface; Multi-Function Inputs 1 to 6 (15 steps, Jog, up/down)
|
|
Operation Setting Signal
|
Keypad
|
Set by RUN, STOP and JOG
|
|
External Signal
|
2 wires/3 wires (Fwd, Rev, EF), JOG operation, RS-485 serial interface (MODBUS), process logic control
|
|
Multi-Function Input Signal
|
Multi-step selection 0 to 15, Jog, accel/decel inhibit, first to forth accel/decel switches, counter, PLC operation, external Base Block (NC, NO), auxiliary motor control is invalid, ACI/AVI/AUI selections, driver reset, UP/DOWN key settings, sink/source selection and reel diameter initialization
|
|
Multi-Function Output Indication
|
AC drive operating, frequency attained, non-zero, Base Block, fault indication, local/remote indication, PLC operation indication, auxiliary motor output, driver is ready, overheat alarm, emergency stop and signal loss alarm
|
|
Analog Output Signal
|
Output frequency/current/voltage/frequency command/speed/factor
|
|
Alarm Output Contact
|
Contact will be On when it malfunctions (1 Form C contact or 3 open collector outputs)
|
|
Operation Functions
|
AVR, accel/decel S-Curve, over-voltage/over-current stall prevention, fault records, reverse inhibition, momentary power loss restart, DC brake, auto torque/slip compensation, auto tuning, adjustable carrier frequency, output frequency limits, parameter lock/reset, vector control, counter, PG feedback control, PID control, fan & pump control, external counter, PLC, MODBUS communication, abnormal reset, abnormal re-start, power-saving, sleep/revival function, digital frequency output, fan control, sleep/wake frequency, master/auxiliary frequency, 1st/2nd frequency source selections
|
|
Protection Functions
|
Over voltage, over current, under voltage, under current, external fault, overload, ground fault, overheating, electronic thermal, IGBT short circuit
|
|
Display Keypads
|
8-key, 7-segment LED with 5-digit, 8 status LEDs, master frequency, output frequency, output current, custom units, parameter values for setup and lock, faults, RUN, STOP, RESET, FWD/REV, JOG
|
|
Enviromental Conditions
|
Enclosure Rating
|
IP20
|
|
Pollution Degree
|
2
|
|
Installation Location
|
Altitude 1,000 m or lower, keep from corrosive gasses, liquid and dust
|
|
Ambient Temperature
|
-10oC to 40oC Non-Condensing and not frozen
|
|
Storage/ Transportation Temperature
|
-20 oC to 60 oC
|
|
Ambient Humidity
|
Below 90% RH (non-condensing)
|
|
Vibration
|
9.80665m/s2 (1G) less than 20Hz, 5.88m/s2 (0.6G) at 20 to 50Hz
|
|
Approvals
|

|
|
|
|
File Name |
Issue Date |
Language |
File Size |
|
VFD-B Full Manual
|
7/25/2008
|
English
|
4.36M
|
|
VFD-B Quick Start Manual
|
7/25/2008
|
English
|
0.82M
|
|
|
File Name |
Issue Date |
Language |
File Size |
|
VFD-B Brochure
|
10/12/2005
|
English
|
2.49M
|
|
|
File Name |
Issue Date |
Language |
File Size |
|
VFD Software User Manual
|
11/15/2007
|
English
|
5.95M
|
|
VFD Software V.1.42
|
12/30/2008
|
English
|
28.97M
|
|
|
Delta Products Corporation
P.O. Box 12173
5101 Davis Drive
Research Triangle Park, NC 27709
Phone: 919-767-3813
Fax: 919-767-3969
Email: IABUsupport@delta-corp.com